Kestrel 4100 Weather Anemometer measures everything you need to know on a job site!

Features & Applications:

The Kestrel 4100 Weather Anemometer is the new revolution in HVAC monitoring.

Features:

  • Air flow in cfm, L/s, m³/s, m³/m, m³/h
  • Air Velocity in ft/m, mph, m/s, km/h, kts, Beaufort
  • Temperature in °F or °C
  • Humidity in %
  • Additional measurements of dewpoint, wind chill and heat stress index
  • Data Logger (automatic and manual)
  • Minimum, Maximum and Average values
  • Multi-Function 3-line display
  • Impeller can be replaced without tools
  • Graphical Display for logged values
  • Upload to a computer (with optional interface)
  • Backlight for low light conditions
  • Includes neck and wrist lanyards, protective pouch and 2 AAA batteries
  • Assembled in the USA

Applications:

  • Crop dusting & spraying
  • Fire fighting
  • Mining ventilation
  • Ventilation (HVAC)
  • Education

Spec Summary:

Air Velocity
Accuracy: ±3%
Response Time: 1 second
Calibration Drift: <2% after 100 hours use at 7m/s
Knots: 0.6 to 78
Meters per Second: 0.3 to 40
Kilometers per Hour: 1.0 to 144
Miles per Hour: 0.7 to 89
Feet per Minute: 59 to 7877
Beaufort Force: 1 to 16
Air Flow
Accuracy; ±3%
Response Time: 1 second
Calibration Drift: <2% after 100 hours use at 7m/s
Cubic Feet per Minute: 0 to 99,999
Liters per Second: 0 to 99,999
Cubic Meters per Second: 0 to 99,999
Cubic Meters per Minute: 0 to 99,999
Cubic Meters per Hour: 0 to 99,999
Temperature
Accuracy:
Temperature: ±1°C
Wind Chill: ±1°C
Dew Point: ±2°C
Heat Index: ±3°C
Response Time: Approximately 1 minute for most conditions
Celsius: -29 to 70
Fahrenheit: -20 to 158
Relative Humidity
Accuracy: ±3%
Response Time: Approximately 1 minute for most conditions
Calibration Drift: ±2% over 24 months (can be field calibrated)
Percent: 5 to 95%
Display
Update: 1 second
Temperature Range: Normal operation from  -4 to 140°F [-20 to 60°C]. Below -4°F [-20°C], 
accurate readings may be taken by keeping the unit warmer than 
-4°F [ -20°C] and exposing it for the minimum time necessary to take 
a reading (less than 1 minute).
Storage Temperature: -22°F to 140°F [-30°C to 60°C].
Auto Shutdown: After 15 minutes of no button presses. (This feature can be disabled.)
Physical
Battery: Two AAA alkaline batteries (included). Typical life, 400 hours
Impeller: 1in. [25 mm.] diameter, sapphire bearings, light weight. 
User-replaceable impeller/housing assembly
Temperature Sensor: Hermetically sealed precision thermistor.
Humidity Sensor: Solid state silicon capacitive sensor
Dimensions: 5 x 1.8 x 1.1 in. [12.7 x 4.5 x 2.8 cm.]
Weight: 3.6 oz. [102 g.]

*Specifications are subject to change.